Installing
FLEXlm server and client license software Application Note 177
|
FLEXlm server-side installationNote: You will need to be logged into the server with Administrator privileges to perform this installation This application note describes a simple FLEXLm server-side installation for both the Polar Si8000m/Si9000e and for Interface Module products that incorporate the Polar Impedance Calculation engine. Where setup differences occur between these two installation procedures, information that applies to the Interface Module installation will be displayed in Interface Module information boxes (as shown below). Full details of the FlexLm product capabilities are contained in the the FlexLm User Manual or on the www.macrovision.com web site. Step
1 Step 2
LMTOOLS dialog box Step 3
System Settings page The System Settings page displays critical information about the selected server machine, including the Computer/Hostname and the Ethernet (MAC) address. Where more than one Ethernet address is reported (for example, if there are multiple network interface cards installed, each serving a separate network segment) it will be necessary to select one address as license server. Note that the FLEXlm server will then only serve licenses to machines connected to the network segment associated with that address. Click the Save HOSTID Info to a File button. Choose a location for the file and click Save. This will create a text file that you will need to email to: PolarCare@polarinstruments.com For installations where the client nodes are specified it will be necessary to run LMTOOLS on each client machine and include each HOSTID file (which must contain the client machine ethernet address) with the email message above. The license manager will serve licenses only to the specified nodes. Note: Please also include within the email the Company Name that you would like associated with the licence file. Failure to do this will result in a delay in issuing the licence. Once Polar Instruments has received and processed this information you will be returned a custom licence file by email. Note: Until the custom licence file is correctly installed on the server machine the software cannot be used. The custom licence file is tied to the nominated server machine and cannot be used on any other server. Interface Module
information Step 4 Select the Config Services tab
Config Services tab In the Service Name dropdown enter the service name: In this example we install the Polar Si8000m so enter Polar Si8000m as the service name. Use the three Browse buttons to select the lmgrd.exe file, the Si8000m.lic file and the Polar Si8000m.log file.Interface Module
information Select the Use Services and Start Server at Power Up checkboxes. Before leaving this page select the Save Service button to store these settings. Step 5
Start/Stop/Reread tab Select the Start Server button; this should be the only time that you are required to do this as this service will be now be run at the time of server start up. Step 6
This completes the server side installation; please refer to the FLEXlm User Manual for additional information. Note:
If a Microsoft Windows XP SP2 machine is to be used as the server it
will be necessary to add the FlexLM License Start Control Panel, Choose Windows Security Center | Windows Firewall | Exceptions | Programs and Services. Click Add Program...and browse to each program file; change the scope as required. |
|
Activating the FLEXlm client Before activating a FLEXlm client ensure:
To install the client software run the SETUP.EXE program from the CDROM root folder or the downloaded file. If you have received the files by email or download (usually in compressed format) extract the files to a suitable folder and run SETUP.EXE from that folder. Follow the on-screen instructions to complete the installation. Start the program by double-clicking the associated desktop icon. The FLEXlm License finder asks for the name of the License Server or License File when the program is first run (or when the first calculation is performed).
Ensure the Specify the License File option is selected and press Next.
Enter the name of the License Server (or click the Browse button and navigate to the machine and folder containing the license file) and press Next. The software will perform calculations within the terms of the license purchased. |
Polar Instruments Ltd www.polarinstruments.com Tel: +44 1481 253081 Fax: +44 1481 252476 |
![]() |
| © Polar Instruments 2004. Polar Instruments pursues a policy of continuous improvement. The specifications in this document may therefore be changed without notice. All trademarks recognised. | |